{"id":15044,"date":"2022-03-10T15:29:35","date_gmt":"2022-03-10T21:29:35","guid":{"rendered":"https:\/\/www.apexengineeringproducts.com\/?p=15044"},"modified":"2022-03-10T15:29:35","modified_gmt":"2022-03-10T21:29:35","slug":"cooling-tower-chiller-descaling","status":"publish","type":"post","link":"https:\/\/www.apexengineeringproducts.com\/cooling-tower-chiller-descaling\/","title":{"rendered":"Cooling Tower, Chiller &#038; Condenser Descaling"},"content":{"rendered":"<div class=\"wpb-content-wrapper\"><p>[vc_row][vc_column][vc_column_text]<\/p>\n<h2>Cooling Tower &amp; Chiller Descaling<\/h2>\n<p>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<span style=\"font-weight: 400;\">An <a href=\"https:\/\/www.youtube.com\/watch?v=5_Jfn9fZwpQ\">evaporative condenser<\/a> is designed to condense a refrigerant gas and a fluid cooler cools process water contained on the inside of the unit&#8217;s tubes. The water is circulated from the basin located at the bottom of the unit up to the top and distributed by spray nozzles to optimize tube cooling coverage.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">The spray nozzles will distribute the water evenly over the tube bundle located midsection on the inside of the unit. The fan on the top of the unit is used to pull air through the side louvers, enhancing evaporation, resulting in further cooling of the water during its descent to the basin.\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Scale deposits form on the exterior tube surfaces of a heat exchange coil, which acts as an insulating barrier. The ultimate result is inadequate cooling, overworked machinery, and expensive, inefficient operation. Scale also restricts the spray coverage of the nozzles at the top of the unit, resulting in the water not flowing over the entire tube surface. This will cause channeling and further minimizing cooling capacity. A scaled evaporative condenser or fluid cooler cannot efficiently cool the water or condense the refrigerant gas inside the tubes<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Studies have shown a scale thickness of only 1\/32\u201d will reduce the heat transfer coefficient of an evaporative condenser by approximately 16%! Reduction of efficiency directly relates to added energy consumption and higher energy bills.<\/span>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_video link=&#8221;https:\/\/www.youtube.com\/watch?v=5_Jfn9fZwpQ&#8221; align=&#8221;center&#8221; css_animation=&#8221;fadeIn&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h2><span style=\"font-weight: 400;\">What is a Cooling Tower?<\/span><\/h2>\n<p><span style=\"font-weight: 400;\">The basic principle of a <a href=\"https:\/\/www.apexengineeringproducts.com\/cooling-tower-cleaning\/\">cooling tower<\/a> is to cool the water that has picked up heat generated by equipment within the facility. The operation begins in the tower basin where the cooled water is pumped out into the facility and utilized for cooling the equipment on the tower system.\u00a0<\/span><\/p>\n<p><span style=\"font-weight: 400;\">As that equipment is cooled, the water picks up the heat and returns to the top of the cooling tower. The hot water is distributed onto a hot deck or through the sprayer nozzles that evenly distribute it over the tower fill media. The tower fill media is designed to increase surface area, as well as contact time between air and water. This enhances evaporation and allows further cooling of the tower water. The water then falls into the tower basin where it is then pumped back into the facility continuing to cool the equipment.<\/span><\/p>\n<p><span style=\"font-weight: 400;\">Scaling within a cooling tower can restrict the water distribution of spray nozzles, reduce the water flow through the openings of a hot deck and restrict the airflow within the tower. All of these conditions will result in diminished cooling capacity and inefficient operation of the associated equipment on the cooling tower system.<\/span>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_video link=&#8221;https:\/\/www.youtube.com\/watch?v=BoueAjuvAnQ&#8221; align=&#8221;center&#8221; css_animation=&#8221;fadeIn&#8221;][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h2><span style=\"font-weight: 400;\">Descaling <a href=\"https:\/\/www.apexengineeringproducts.com\/chiller-cleaning\/\">Chillers<\/a> &amp; <a href=\"https:\/\/www.apexengineeringproducts.com\/condenser-descaler\/\">Condensers<\/a> with <a href=\"https:\/\/www.apexengineeringproducts.com\/product\/rydlyme-biodegradable-descaler\/\"><em><strong>RYDLYME<\/strong><\/em><\/a><\/span><\/h2>\n<p><span style=\"font-weight: 400;\">The following is a detailed procedure for cleaning a cooling tower system or an evaporative condenser\/fluid cooler with <strong><em>RYDLYME<\/em><\/strong>. To ensure a successful cleaning, please contact Apex Engineering Products Corporation for technical assistance prior to starting the cleaning procedure.<\/span><\/p>\n<ol>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Close the water valve-to-tower basin.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Turn off all chemical or non-chemical water treatment, conductivity meters and pH meters.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">It is recommended that all loose water scale, lime, mud, rust and other foreign matter be manually removed from tower basin prior to starting the cleaning.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Lower the water level in the tower basin to a point where the pump can maintain circulation without cavitation and close the bleed-off valve.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">It is recommended that the fans be turned off during the cleaning.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Determine the proper amount of <strong><em>RYDLYME<\/em><\/strong> to be added to the system. Please note that the amounts recommended in the chart are just guidelines and that your application may require 2-4 times the chart amount, depending on the severity of the deposit build-up in your system.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">To minimize excessive foaming, you may slowly add required amount of <strong><em>RYDLYME<\/em><\/strong> to the tower basin.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">The bubbling and foaming you will observe is a natural reaction of the <strong><em>RYDLYME<\/em><\/strong> dissolving the water formed mineral deposits within the system.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Once the <strong><em>RYDLYME<\/em><\/strong> is in the tower system, allow it to circulate. Start charting your pH readings or performing calcium spot tests to measure the effectiveness of the <strong><em>RYDLYME<\/em><\/strong> solution as the cleaning solution expends prior to the completion of the recommended circulation time, there is more scale in the system. It is recommended that you repeat steps 6-9 to complete the cleaning.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">It is recommended that the <strong><em>RYDLYME<\/em><\/strong> cleaning solution be cycled out of the system to prepare it for normal operation. At this time, strainers should also be removed, inspected and cleaned as well.<\/span><\/li>\n<li style=\"font-weight: 400;\" aria-level=\"1\"><span style=\"font-weight: 400;\">Once the cleaning material has been cycled from the tower system, turn your conductivity, pH meters or any other equipment back on. Return the make-up water and bleed off valves per the manufacturer\u2019s recommendations. Lastly, resume normal system operation.\u00a0<\/span><\/li>\n<\/ol>\n<p><span style=\"font-weight: 400;\"><strong>CAUTION<\/strong>: <strong><em>RYDLYME<\/em><\/strong> is non-corrosive, but the application of <strong><em>RYDLYME<\/em><\/strong> may expose pre-existing under deposit corrosion (pitting, holes or similar damage) that can result in leaks in pipes, equipment or systems.<\/span><\/p>\n<p><a href=\"http:\/\/apexengineeringproducts.com\/wp-content\/uploads\/2021\/01\/ChillersAndCondensers_JAN2021_Vertical.pdf\"><span style=\"font-weight: 400;\">View more information in PDF.<\/span><\/a>[\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]<\/p>\n<h2><span style=\"font-weight: 400;\"><em><strong>RYDLYME<\/strong> <\/em>The World\u2019s Leading Descalcificador biodegradable<\/span><\/h2>\n<p><span style=\"font-weight: 400;\">For more than 80 years, <em><strong>RYDLYME<\/strong><\/em> has been the most trusted brand for removing scale from boilers, cooling towers, heat exchangers, condensers, chillers, and so much more. If you have further questions pertaining to the effectiveness of \u201cThe World\u2019s Leading Descalcificador biodegradable,\u201d <em><strong>RYDLYME<\/strong><\/em>, please feel free to <\/span><a href=\"https:\/\/www.apexengineeringproducts.com\/contact-us\/\"><span style=\"font-weight: 400;\">contact our main office<\/span><\/a><span style=\"font-weight: 400;\">.<\/span>[\/vc_column_text][\/vc_column][\/vc_row]<\/p>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>[vc_row][vc_column][vc_column_text] Cooling Tower &amp; Chiller Descaling [\/vc_column_text][\/vc_column][\/vc_row][vc_row][vc_column][vc_column_text]An evaporative condenser is designed to condense a refrigerant [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":4608,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[17,18],"tags":[],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v21.6 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Cooling Tower, Chiller &amp; Condenser Descaling | Apex Engineering Products<\/title>\n<meta name=\"description\" content=\"Cooling Tower &amp; Chiller Descaling in the same loop with RYDLYME! Find out how with our thorough procedures and videos!\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.apexengineeringproducts.com\/cooling-tower-chiller-descaling\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Cooling Tower, Chiller &amp; Condenser Descaling | Apex Engineering Products\" \/>\n<meta property=\"og:description\" content=\"Cooling Tower &amp; Chiller Descaling in the same loop with RYDLYME! Find out how with our thorough procedures and videos!\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.apexengineeringproducts.com\/cooling-tower-chiller-descaling\/\" \/>\n<meta property=\"og:site_name\" content=\"Apex Engineering Products\" \/>\n<meta property=\"article:published_time\" content=\"2022-03-10T21:29:35+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.apexengineeringproducts.com\/wp-content\/uploads\/2020\/01\/Cooling-Tower-Blowdown-Line-RYDLYME.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2000\" \/>\n\t<meta property=\"og:image:height\" content=\"1151\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Apex Team\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Apex Team\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.apexengineeringproducts.com\/cooling-tower-chiller-descaling\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.apexengineeringproducts.com\/cooling-tower-chiller-descaling\/\"},\"author\":{\"name\":\"Apex Team\",\"@id\":\"https:\/\/www.apexengineeringproducts.com\/#\/schema\/person\/70263e8eaeb365bf58658deec483d037\"},\"headline\":\"Cooling Tower, Chiller &#038; Condenser Descaling\",\"datePublished\":\"2022-03-10T21:29:35+00:00\",\"dateModified\":\"2022-03-10T21:29:35+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.apexengineeringproducts.com\/cooling-tower-chiller-descaling\/\"},\"wordCount\":995,\"publisher\":{\"@id\":\"https:\/\/www.apexengineeringproducts.com\/#organization\"},\"articleSection\":[\"RYDLYME\",\"RYDLYME Descaling Systems\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.apexengineeringproducts.com\/cooling-tower-chiller-descaling\/\",\"url\":\"https:\/\/www.apexengineeringproducts.com\/cooling-tower-chiller-descaling\/\",\"name\":\"Cooling Tower, Chiller & Condenser Descaling | Apex Engineering Products\",\"isPartOf\":{\"@id\":\"https:\/\/www.apexengineeringproducts.com\/#website\"},\"datePublished\":\"2022-03-10T21:29:35+00:00\",\"dateModified\":\"2022-03-10T21:29:35+00:00\",\"description\":\"Cooling Tower & Chiller Descaling in the same loop with RYDLYME! Find out how with our thorough procedures and videos!\",\"breadcrumb\":{\"@id\":\"https:\/\/www.apexengineeringproducts.com\/cooling-tower-chiller-descaling\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.apexengineeringproducts.com\/cooling-tower-chiller-descaling\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.apexengineeringproducts.com\/cooling-tower-chiller-descaling\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.apexengineeringproducts.com\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Cooling Tower, Chiller &#038; Condenser Descaling\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.apexengineeringproducts.com\/#website\",\"url\":\"https:\/\/www.apexengineeringproducts.com\/\",\"name\":\"Apex Engineering Products\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/www.apexengineeringproducts.com\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.apexengineeringproducts.com\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.apexengineeringproducts.com\/#organization\",\"name\":\"Apex Engineering Products\",\"url\":\"https:\/\/www.apexengineeringproducts.com\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.apexengineeringproducts.com\/#\/schema\/logo\/image\/\",\"url\":\"http:\/\/apexengineeringproducts.com\/wp-content\/uploads\/2022\/12\/logo.webp\",\"contentUrl\":\"http:\/\/apexengineeringproducts.com\/wp-content\/uploads\/2022\/12\/logo.webp\",\"width\":600,\"height\":218,\"caption\":\"Apex Engineering Products\"},\"image\":{\"@id\":\"https:\/\/www.apexengineeringproducts.com\/#\/schema\/logo\/image\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.apexengineeringproducts.com\/#\/schema\/person\/70263e8eaeb365bf58658deec483d037\",\"name\":\"Apex Team\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.apexengineeringproducts.com\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/ead2b08280c08bbab70e97e7f6b3025f?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/ead2b08280c08bbab70e97e7f6b3025f?s=96&d=mm&r=g\",\"caption\":\"Apex Team\"},\"url\":\"https:\/\/www.apexengineeringproducts.com\/author\/guyhaines\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Cooling Tower, Chiller & Condenser Descaling | Apex Engineering Products","description":"Cooling Tower & Chiller Descaling in the same loop with RYDLYME! Find out how with our thorough procedures and videos!","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.apexengineeringproducts.com\/cooling-tower-chiller-descaling\/","og_locale":"en_US","og_type":"article","og_title":"Cooling Tower, Chiller & Condenser Descaling | Apex Engineering Products","og_description":"Cooling Tower & Chiller Descaling in the same loop with RYDLYME! Find out how with our thorough procedures and videos!","og_url":"https:\/\/www.apexengineeringproducts.com\/cooling-tower-chiller-descaling\/","og_site_name":"Apex Engineering Products","article_published_time":"2022-03-10T21:29:35+00:00","og_image":[{"width":2000,"height":1151,"url":"https:\/\/www.apexengineeringproducts.com\/wp-content\/uploads\/2020\/01\/Cooling-Tower-Blowdown-Line-RYDLYME.jpg","type":"image\/jpeg"}],"author":"Apex Team","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Apex Team","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.apexengineeringproducts.com\/cooling-tower-chiller-descaling\/#article","isPartOf":{"@id":"https:\/\/www.apexengineeringproducts.com\/cooling-tower-chiller-descaling\/"},"author":{"name":"Apex Team","@id":"https:\/\/www.apexengineeringproducts.com\/#\/schema\/person\/70263e8eaeb365bf58658deec483d037"},"headline":"Cooling Tower, Chiller &#038; Condenser Descaling","datePublished":"2022-03-10T21:29:35+00:00","dateModified":"2022-03-10T21:29:35+00:00","mainEntityOfPage":{"@id":"https:\/\/www.apexengineeringproducts.com\/cooling-tower-chiller-descaling\/"},"wordCount":995,"publisher":{"@id":"https:\/\/www.apexengineeringproducts.com\/#organization"},"articleSection":["RYDLYME","RYDLYME Descaling Systems"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.apexengineeringproducts.com\/cooling-tower-chiller-descaling\/","url":"https:\/\/www.apexengineeringproducts.com\/cooling-tower-chiller-descaling\/","name":"Cooling Tower, Chiller & Condenser Descaling | Apex Engineering Products","isPartOf":{"@id":"https:\/\/www.apexengineeringproducts.com\/#website"},"datePublished":"2022-03-10T21:29:35+00:00","dateModified":"2022-03-10T21:29:35+00:00","description":"Cooling Tower & Chiller Descaling in the same loop with RYDLYME! Find out how with our thorough procedures and videos!","breadcrumb":{"@id":"https:\/\/www.apexengineeringproducts.com\/cooling-tower-chiller-descaling\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.apexengineeringproducts.com\/cooling-tower-chiller-descaling\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.apexengineeringproducts.com\/cooling-tower-chiller-descaling\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.apexengineeringproducts.com\/"},{"@type":"ListItem","position":2,"name":"Cooling Tower, Chiller &#038; Condenser Descaling"}]},{"@type":"WebSite","@id":"https:\/\/www.apexengineeringproducts.com\/#website","url":"https:\/\/www.apexengineeringproducts.com\/","name":"Apex Engineering Products","description":"","publisher":{"@id":"https:\/\/www.apexengineeringproducts.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.apexengineeringproducts.com\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.apexengineeringproducts.com\/#organization","name":"Apex Engineering Products","url":"https:\/\/www.apexengineeringproducts.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.apexengineeringproducts.com\/#\/schema\/logo\/image\/","url":"http:\/\/apexengineeringproducts.com\/wp-content\/uploads\/2022\/12\/logo.webp","contentUrl":"http:\/\/apexengineeringproducts.com\/wp-content\/uploads\/2022\/12\/logo.webp","width":600,"height":218,"caption":"Apex Engineering Products"},"image":{"@id":"https:\/\/www.apexengineeringproducts.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.apexengineeringproducts.com\/#\/schema\/person\/70263e8eaeb365bf58658deec483d037","name":"Apex Team","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.apexengineeringproducts.com\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/ead2b08280c08bbab70e97e7f6b3025f?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/ead2b08280c08bbab70e97e7f6b3025f?s=96&d=mm&r=g","caption":"Apex Team"},"url":"https:\/\/www.apexengineeringproducts.com\/author\/guyhaines\/"}]}},"_links":{"self":[{"href":"https:\/\/www.apexengineeringproducts.com\/wp-json\/wp\/v2\/posts\/15044"}],"collection":[{"href":"https:\/\/www.apexengineeringproducts.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.apexengineeringproducts.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.apexengineeringproducts.com\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/www.apexengineeringproducts.com\/wp-json\/wp\/v2\/comments?post=15044"}],"version-history":[{"count":0,"href":"https:\/\/www.apexengineeringproducts.com\/wp-json\/wp\/v2\/posts\/15044\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.apexengineeringproducts.com\/wp-json\/wp\/v2\/media\/4608"}],"wp:attachment":[{"href":"https:\/\/www.apexengineeringproducts.com\/wp-json\/wp\/v2\/media?parent=15044"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.apexengineeringproducts.com\/wp-json\/wp\/v2\/categories?post=15044"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.apexengineeringproducts.com\/wp-json\/wp\/v2\/tags?post=15044"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}